Menu description
Leuze electronic
BCL 604i
43
Parameter enable
During normal operation parameters can only be viewed. If parameters need to be changed, the ON menu
item in the Parameter enabling menu must be activated.
In the Parameter menu, select Parameter handling.
Press the enter button to enter the menu.
Select the Parameter enable menu item.
Press the enter button to enter the menu.
Select the ON menu item.
Press the enter button to enter the menu.
The PWR LED lights up red. You can now set individual parameters via the display.
Press the Escape button twice to return to the main menu.
Password for parameter enabling
The password query is deactivated by default. To protect against unwanted changes, the password query
can be activated. The preset password is 0000 and can be changed as necessary . To switch on password
protection, proceed as follows:
Setting the password
Use the navigation buttons
to move through the menu. Activate the desired selection with
the enter button .
If a password was stored, parameter enabling is not possible until this password is entered (see
chapter 8.6 "Operation", Password for parameter enabling).
The device is deactivated on the PROFIBUS if parameter enabling is activated via the display.
The device is reactivated on the PROFIBUS after parameter enabling is exited.
In the PROFIBUS network, configuration is performed exclusively via the PROFIBUS.
Parameters set via the display when operating the device on the PROFIBUS are overwritten by
the parameters set in the GSD modules. For GSD modules which are not actively used on the
PROFIBUS, the default settings of the bar code reader apply (see chapter 10.5 "Overview of the
project modules"). Thus, the PROFIBUS presets values to all parameters.
If parameters are changed via the display during bus operation, the device is separated from the
PROFIBUS at the moment parameter enabling is activated via the display. Parameters set by
the PROFIBUS are moved to the background, and changes to parameters can be made via the
display. When parameter enabling is exited, the device is automatically reconnected to the PRO
-
FIBUS. Upon connection to the PROFIBUS, the device receives all parameters from the PRO
-
FIBUS controller.
Changes made via the display are overwritten!
Device settings for operating the device on the PROFIBUS are managed and configured exclu
-
sively by the PROFIBUS controller.
In order to enter the password, parameter enabling must be activated.
A selected password is saved with save.
If the password is not known, the master password 2301 can always be used to enable the de
-
vice.