Starting up the device - Configuration
Leuze electronic
BCL 604i
71
Input data
Table 10.29:
Input data for module 39
Input data length
1 byte
Output data
None
10.8.13Module 40 – Code type
Description
The module defines the input data for the communication of the code type of the currently transmitted bar
code.
Parameter
None
Input data
Table 10.30:
Input data for module 40
Input data length
1 byte
Output data
None
10.8.14Module 41 – Code position in the swivel range
Description
The module defines input data for the communication of the relative bar code position in the swivel range
of an oscillating mirror device.
Parameter
None
Input data
Table 10.31:
Input data for module 41
Input data length
2 bytes
Input data
Description
Addr.
Data type
Value range
Init value Unit
Number of digits
Number of digits of the transmitted bar code
0
UNSIGNED8
0 … 48
0
-
Input data
Description
Addr.
Data type
Value range
Init value Unit
Code type
Code type of the transmitted bar code
0
UNSIGNED8
0: No code
1: 2/5 Interleaved
2: Code39
6: UPC, UPCE
7: EAN8, EAN13
8: Code128, EAN128
10: EAN Addendum
11: Codabar
12: Code93
13: RSS-14
14: RSS Limited
15: RSS Expanded
0
-
Input data
Description
Addr.
Data type
Value range
Init value Unit
Position in the
swivel range
Relative position of the bar code in the swivel
range. The position is normalized to the zero
position (middle position). Specified in 1/10
degrees.
0 … 1
SIGNED16
-200 … +200
0
1/10°