Starting up the device - Configuration
Leuze electronic
BCL 604i
57
10.6 Decoder modules
10.6.1 Modules 1-4 – Code table extensions 1 to 4
Description
The modules extend the code type tables of the device parameters and permit the additional definition of
further 4 code types together with the respective number of digits.
Display
Display parameter settings
62
3
0
0
Alignment
Alignment mode
63
0
1
1
Oscillating mirror
Configuration of the oscillating mirror
64
6
0
0
Deflection mirror
Deflection mirror parameter settings
65
2
0
0
Switching inputs/outputs SWIO
Switching input/output SWIO1
Parameter settings SWIO1
70
23
0
0
Switching input/output SWIO2
Parameter settings SWIO2
71
23
0
0
Switching input/output SWIO3
Parameter settings SWIO3
72
23
0
0
Switching input/output SWIO4
Parameter settings SWIO4
73
23
0
0
SWIO status and control
Handling of switching input and switching output
signals
74
0
2
2
Data output
Sorting
Sorting support
80
3
0
0
Reference code comparator 1
Definition of the operation mode of reference
code comparator 1
81
8
0
0
Reference code comparator 2
Definition of the operation mode of reference
code comparator 2
82
8
0
0
Reference code comparison pattern 1
Definition of the 1st comparison pattern
83
31
0
0
Reference code comparison pattern 2
Definition of the 2nd comparison pattern
84
31
0
0
Special Functions
Status and control
Grouping of multiple status and control bits
90
0
1
0
AutoReflAct
Automatic reflector activation
91
2
0
0
AutoControl
Automatic monitoring of the reading properties
92
3
1
0
a) The number of parameter bytes does not include the constant module number, which is always transmitted in addition.
Module
Description
Module
identifier
Parame
-
ter
a)
Outp.
data
Inp. data
For the standard case, at least module 10 (activation) and one of modules 21 … 27 (decoding
result 1 … 7) should be integrated.