Starting up the device - Configuration
Leuze electronic
BCL 604i
98
Input data length:
1 byte
Output data
None
10.15.2Module 91 – AutoReflAct (automatic reflector activation)
Description
The module defines the mode of operation of the laser scanner for controlling the reading gate.
The AutoReflAct function uses the scanning beam to simulate a photoelectric sensor and thus permits an
activation without additional sensory mechanism. This is achieved by directing the scanner with reduced
scanning beam towards a reflector mounted behind the conveyor path. As long as the scanner is targeted
at the reflector, the reading gate remains closed. If, however, the reflector is blocked by an object such as
a container with a bar code label, the scanner activates the read procedure, and the label on the container
is read. When the path from the scanner to the reflector has cleared, the read procedure has completed
and the scanning beam is reduced and again directed onto the reflector. The reading gate is closed.
Parameter
Table 10.60:
Parameters for module 91 – AutoreflAct
Parameter length
2 bytes
Input data
None
Output data
None
10.15.3Module 92 – AutoControl
Description
The module defines the mode of operation of the function AutoControl. The function monitors the quality
of the decoded bar codes and compares these with a limit value. If the limit is reached, a status is set.
Reserved
Free
0.3
Bit
0
-
RefCode compari
-
son state 1
The signal indicates whether the decoded bar
code corresponds to the reference code with
regard to the comparison criteria as defined in
the comparison function 1. If it matches, the
value 1 is output.
0.4 … 0.5
Bit
0: Not equal
1: Equal
2: Unknown
2
-
RefCode compari
-
son state 2
The signal indicates whether the decoded bar
code corresponds to the reference code with
regard to the comparison criteria as defined in
the comparison function 2. If it matches, the
value 1 is output.
0.6 … 0.7
Bit
0: Not equal
1: Equal
2: Unknown
2
-
Input data
Description
Addr.
Data type
Value range
Init value Unit
Parameter
Description
Addr.
Data type
Value range
Default
Unit
Mode
This parameter activates the function of the
laser scanner.
If “Autom. reading gate control” is set as the
parameter value, the device activates the
reading gate automatically if the reflector is
obscured.
0
UNSIGNED8
0: Normal - AutoreflAct
switched off.
1: Auto - AutoreflAct acti
-
vated. Autom. reading
gate control.
2: Manual - AutoreflAct
activated. No reading gate
control, signaling only.
0
-
Debouncing
The parameter defines the debounce time in
scans for the reflector detection.
With a motor speed of 1000, 1 scan corre
-
sponds to a debounce time of 1 ms.
1
UNSIGNED8
1 … 16
5
-