Starting up the device - Configuration
Leuze electronic
BCL 604i
91
Parameter length
23 byte
Input data
None
Output data
None
Comment
The DC bias level also defines whether the output is low-active (0) or high-active (1).
Switching on an I/O configured as an output means switching to the active state; switching off, on the other
hand, results in switching to the inactive or idle state.
10.12.9Module 74 – SWIO status and control
Description
Module for handling switching input and switching output signals.
Parameter
None
Input data
Table 10.52:
Input data for module 74 Input/output status and control
Minimum switch-on
time
The parameter defines a minimum time period
before the signal is reset.
18
UNSIGNED16 0 … 65535
0
ms
Delay off time
The parameter defines a time delay for the sig
-
nal during switch-off.
20
UNSIGNED16 0 … 65535
0
ms
Input function
The parameter specifies the function which is
to be activated or deactivated by a change of
state in the signal.
22
UNSIGNED8
0
-
Parameter
Description
Addr.
Data type
Value range
Default
Unit
Parameter
Description
Addr.
Data type
Value range
Init value Unit
State 1
Signal state of switching input or output 1
0.0
Bit
0.1
0
-
State 2
Signal state of switching input or output 2
0.1
Bit
0.1
0
-
State 3
Signal state of switching input or output 3
0.2
Bit
0.1
0
-
State 4
Signal state of switching input or output 4
0.3
Bit
0.1
0
-
Comparison state
switching output 1
(Event Counter)
Indicates whether the event counter has
exceeded the set comparative value.
The bit is reset to the init. value by resetting
the event counter.
1.0
Bit
0: Not exceeded
1: Exceeded
0
-
Switching output 1
Comparison state tog
-
gle bit
(Event Counter)
If “SWOUT switches several times” was con
-
figured as comparison mode, this bit is toggled
each time the event counter is exceeded.
The bit is reset to the init. value by resetting
the event counter.
1.1
Bit
0 -> 1: Event counter
exceeded
1 -> 0: Event counter
exceeded again
0
-
Comparison state
switching output 2
(Event Counter)
Indicates whether the event counter has
exceeded the set comparative value.
The bit is reset to the init. value by resetting
the event counter.
1.2
Bit
0: Not exceeded
1: Exceeded
0
-
Switching output 2
Comparison state tog
-
gle bit
(Event Counter)
If “SWOUT switches several times” was con
-
figured as comparison mode, this bit is toggled
each time the event counter is exceeded.
The bit is reset to the init. value by resetting
the event counter.
1.3
Bit
0 -> 1: Event counter
exceeded
1 -> 0: Event counter
exceeded again
0
-
Comparison state
switching output 3
(Event Counter)
Indicates whether the event counter has
exceeded the set comparative value.
The bit is reset to the init. value by resetting
the event counter.
1.4
Bit
0: Not exceeded
1: Exceeded
0
-