Starting up the device - Configuration
Leuze electronic
BCL 604i
68
Input data
Table 10.21:
Input data for module 31
Input data length
2 byte consistent
Output data
None
10.8.5 Module 32 – Reading gate time
Description
This module returns the time between opening and closing of the last reading gate.
Parameter
None
Input data
Table 10.22:
Input data for module 32
Input data length
2 byte consistent
Output data
None
10.8.6 Module 33 – Code position
Description
The module defines input data for the communication of the relative bar code position in the laser beam.
Parameter
None
Input data
Table 10.23:
Input data for module 33
Input data length
2 byte consistent
Output data
None
Input data
Description
Addr.
Data type
Value range
Init value Unit
Reading gate num
-
ber
The device transmits the current reading gate
number. The reading gate number is initialized
with the system start and is then incremented
continuously. At 65535, an overflow occurs
and the counter starts afresh from 0.
0 … 1
UNSIGNED16 0 … 65535
0
-
Input data
Description
Addr.
Data type
Value range
Init value Unit
Opening duration
of the reading gate
Opening duration of the last reading gate in
ms.
0 … 1
UNSIGNED16 0 … 65535
If the range is exceeded,
the value remains at
65535
0
ms
Input data
Description
Addr.
Data type
Value range
Init value Unit
Code position
Relative position of the bar code in the scanner
beam. The position is normalized to the zero
position (middle position).
Specified in 1/10 degrees.
0 … 1
SIGNED16
±450
0
1/10
degree