Menu description
Leuze electronic
BCL 604i
36
Table 8.1:
Parameter handling submenu
Decoder table
In the Decoder table submenu, 4 different code type definitions can be stored. Bar codes that have been
read can only be decoded if they correspond to one of the definitions stored here.
Table 8.2:
Decoder table submenu
Level 3
Level 4
Level 5
Selection/configuration option
Description
Standard
Parameter enable
OFF/ON
The standard setting (OFF) prevents unintended parameter
changes.
If parameter enabling is activated (ON), parameters can be
changed manually.
As long as parameter enabling is activated, the device is dis
-
connected from the PROFIBUS.
OFF
Default parameters
By pressing the enter button after selecting
Parameters to default, all parameters are reset to their stan
-
dard settings without any further security prompts.
In this case, English is selected as the display language.
Level 3
Level 4
Level 5
Selection/configuration option
Description
Standard
Max. no. of
labels
Value between 0 and 64
The value set here specifies the maximum number of labels that
should be detected for each reading gate.
1
Decoder 1
Symbology
(Code type)
No code
Code 2/5 Interleaved
Code 39
Code 32
Code UPC
Code EAN
Code 128
EAN Addendum
Codabar
Code 93
GS1 DataBar Omnidirectional
GS1 DataBar Limited
GS1 DataBar Expanded
If No code is configured, the current and all subsequent decoders
are deactivated.
Code 2/5i
Number of digits
Interval mode
OFF/ON
With the ON setting, the values in digits 1 and 2 define a range of
character numbers that are to be read.
OFF
Digits 1
0 to 64 characters
First decodable number of characters or lower range limit.
10
Digits 2
0 to 64 characters
Second decodable number of characters or upper range limit.
0
Digits 3
0 to 64 characters
Third decodable number of characters.
0
Digits 4
0 to 64 characters
Fourth decodable number of characters.
0
Digits 5
0 to 64 characters
Fifth decodable number of characters.
0
Reading reliability
Value from 2 to 100
Number or scans required to reliably detect a label.
4
Check digit method
Standard
No check
Depending on the symbology (code type) selected for the decoder,
further calculation algorithms can be selected here.
Check digit method used for the decoding of the bar code that has
been read.
If Standard is set, the check digit method intended for the respec
-
tive code type is used.
Standard
Check digit transmis
-
sion
Standard
Not standard
Specifies whether the check digit is transmitted. Standard means
that the transmission matches the standard intended for the
respective code type.
Standard