Starting up the device - Configuration
Leuze electronic
BCL 604i
87
Parameter length
23 byte
Input data
None
Output data
None
Comment
The DC bias level also defines whether the output is low-active (0) or high-active (1).
Switching on an I/O configured as an output means switching to the active state; switching off, on the other
hand, results in switching to the inactive or idle state.
10.12.6Module 71 – Switching input/output SWIO2
Parameter
Table 10.49:
Parameters for module 71 – Input/Output 2
Minimum switch-
on time
The parameter defines a minimum time period
before the signal is reset.
18
UNSIGNED16 0 … 65535
0
ms
Delay off time
The parameter defines a time delay for the sig
-
nal during switch-off.
20
UNSIGNED16 0 … 65535
0
ms
Input function
The parameter specifies the function which is
to be activated or deactivated by a change of
state in the signal.
22
UNSIGNED8
1
-
Parameter
Description
Addr.
Data type
Value range
Default
Unit
Parameter
Description
Addr.
Data type
Value range
Default
Unit
Function
This parameter defines whether I/O 2 func
-
tions as an input or as an output.
0.0
Bit
0: Input
1: Output
1
-
Mode of operation for configuration as an output
DC bias level
The parameter defines the DC bias level of the
switching output and, thus, simultaneously
whether the output is low-active (0) or high-
active (1).
0.1
Bit
0: LOW (0V)
1: HIGH (+Ub)
0
-
Reserved
Free
0.2 … 0.7
Start-up delay
With this parameter, the output pulse may be
delayed by a set time period.
1
UNSIGNED16 0 … 65535
0
ms
Switch-on time
The parameter defines the switch-on time
period for the switching output. If the value is
0, the signal is static.
3
UNSIGNED16 0 … 1300
400
ms
Switch-on function
1
This parameter specifies an event which can
set the switching output.
5
UNSIGNED8
5
-
Switch-on function
2
This parameter specifies an event which can
set the switching output.
Switch-on function 1 and switch-on function 2
are OR linked.
6
UNSIGNED8
0
-
Switch-off function
1
This parameter specifies an event which can
reset the switching output.
7
UNSIGNED8
1
-
Switch-off function
2
This parameter specifies an event which can
reset the switching output.
Switch-off function 1 and switch-off function 2
are OR linked.
8
UNSIGNED8
0
-
Comparative value
(Event Counter)
If the number of activation events of the
selected switch-on function reaches this com
-
parative value, the switching output is acti
-
vated. A deactivation event of the selected
switch-off function resets the counter.
9
UNSIGNED16 0..65535
0
-