Parameter
Table 10.35:
Parameters for module 53
Parameter
Description
Addr.
Data type
Value range
Default
Unit
Identifier list
Identifier 1
The identifier string is used for the identifier list
and the filtering according to the segmentation.
0
STRING
5 characters
null termi
-
nated
1 … 5 bytes of ASCII
characters
‘*‘
-
Identifier 2
See identifier 1.
5
STRING
5 characters
null termi
-
nated
1 … 5 bytes of ASCII
characters
\0
-
Identifier 3
See identifier 1.
10
STRING
5 characters
null termi
-
nated
1 … 5 bytes of ASCII
characters
\0
-
Identifier 4
See identifier 1.
15
STRING
5 characters
null termi
-
nated
1 … 5 bytes of ASCII
characters
\0
-
Identifier 5
See identifier 1.
20
STRING
5 characters
null termi
-
nated
1 … 5 bytes of ASCII
characters
\0
-
Identifier output
Output with identi
-
fier
If this switch is not set, the output of the identi
-
fiers is suppressed. Only the data values that
belong to the identifiers are displayed in this
case.
25.0
Bit
0: Output of the identifiers
is suppressed.
1: Identifiers are output.
1
-
Output delimiter
This delimiter, if not equal to 0, is inserted
between the identifier and the associated data
value in the output.
26
UNSIGNED8
0 … 127
0
-
Fixed positions
Start position of
the 1st identifier
Specifies the position of the first character of
the first identifier in the data string of the bar
code.
The first character in the bar code has position
1. If the parameter is = 0, it is deactivated.
27
UNSIGNED8
0 … 127
0
-
Start position of
the 1st data value
Specifies the position of the first character of
the first data value in the data string of the bar
code.
The first character in the bar code has position
1. If the parameter is = 0, it is deactivated.
28
UNSIGNED8
0 … 127
0
-
Start position of
the 2nd identifier
Specifies the position of the first character of
the second identifier in the data string of the
bar code.
The first character in the bar code has position
1. If the parameter is = 0, it is deactivated.
29
UNSIGNED8
0 … 127
0
-
Start position of
the 2nd data value
Specifies the position of the first character of
the second data value in the data string of the
bar code.
The first character in the bar code has position
1. If the parameter is = 0, it is deactivated.
30
UNSIGNED8
0 … 127
0
-
Start position of
the 3rd identifier
Specifies the position of the first character of
the third identifier in the data string of the bar
code.
The first character in the bar code has position
1. If the parameter is = 0, it is deactivated.
31
UNSIGNED8
0 … 127
0
-
Start position of
the 3rd data value
Specifies the position of the first character of
the third data value in the data string of the bar
code.
The first character in the bar code has position
1. If the parameter is = 0, it is deactivated.
32
UNSIGNED8
0 … 127
0
-