LSI Corporation
- 355 -
12Gb/s MegaRAID SAS Software User Guide
March 2014
Appendix A: Events and Messages
Appendix A: Events and Messages
This appendix lists the MegaRAID Storage Manager events that can appear in the event log.
MegaRAID Storage Manager software monitors the activity and performance of all controllers in the workstation and
the devices attached to them. When an event occurs, such as the start of an initialization, an event message appears in
the log at the bottom of the MegaRAID Storage Manager main menu window. The messages are also logged in the
Windows Application log (Event Viewer).
A.1
Error Levels
Each message that appears in the event log has a Severity level that indicates the severity of the event, as shown in
the following table.
Table 56 Event Error Levels
A.2
Event Messages
The following table lists all of the MegaRAID Storage Manager event messages. The event message descriptions
include placeholders for specific values that are determined when the event is generated. For example, in message
No. 1 in the Event Messages table, “%s” is replaced by the firmware version, which is read from the firmware when the
event is generated.
Table 57 Event Messages
Severity Level
Meaning
Information
Informational message. No user action is necessary.
Warning
Some component might be close to a failure point.
Critical
A component has failed, but the system has not lost data.
Fatal
A component has failed, and data loss has occurred or will occur.
Number
Severity
Level
Event Text
Generic Conditions when Each Event Occurs
0x0000
Information
MegaRAID firmware initialization
started (PCI ID
%04x/%04x/%04x/%04x)
Logged at firmware initialization.
0x0001
Information
MegaRAID firmware version %s
Logged at firmware initialization to display firmware version.
0x0002
Fatal
Unable to recover cache data from
TBBU
Currently not logged.
0x0003
Information
Cache data recovered from TBBU
successfully
Currently not logged.
0x0004
Information
Configuration cleared
Logged when controller configuration is cleared.
0x0005
Warning
Cluster down; communication with
peer lost
Currently not logged.
0x0006
Information
Virtual drive %s ownership changed
from %02x to %02x
Currently not logged.
0x0007
Information
Alarm disabled by user
Logged when user disables alarm.
0x0008
Information
Alarm enabled by user
Logged when user enables alarm.
Summary of Contents for ThinkServer RD650