LSI Corporation
- 370 -
12Gb/s MegaRAID SAS Software User Guide
March 2014
Appendix A: Events and Messages
0x0171
Warning
%s is not available
Logged when a LD was not available.
0x0172
Information
%s is available
Logged when a LD was available.
0x0173
Information
%s is used for CacheCade with
capacity 0x%lx logical blocks
Logged when a LD was used for CacheCade with the
indicated capacity in logical blocks.
0x0174
Information
%s is using CacheCade %s
Logged when a LD was using CacheCade.
0x0175
Information
%s is no longer using CacheCade %s Logged when a LD was no longer using CacheCade.
0x0176
Critical
Snapshot deleted due to resource
constraints for %s in snapshot
repository %s
Logged when the snapshot is deleted due to resource
constraints in snapshot repository.
0x0177
Warning
Auto Snapshot failed for %s in
snapshot repository %s
Logged when the Auto Snapshot is failed for a VD in
snapshot repository.
0x0178
Warning
Controller reset on-board expander
Logged when the chip reset issued to on-board expander.
0x0179
Warning
CacheCade (%s) capacity changed
and is now 0x%lx logical blocks
Logged when the CacheCade capacity is changed along with
the current capacity.
0x017a
Warning
Battery cannot initiate transparent
learn cycles
Logged when the Battery cannot initiate transparent learn
cycles.
0x017b
Information
Premium feature %s key was applied
for - %s
Logged when the Premium feature key was applied.
0x017c
Information
Snapshot schedule properties
changed on %s
Logged when the Snapshot schedule properties changed.
0x017d
Information
Snapshot scheduled action is due on
%s
Logged when the Snapshot scheduled action is due.
0x017e
Information
Performance Metrics: collection
command 0x%lx
Logged during the Performance Metrics collection.
0x017f
Information
Premium feature %s key was
transferred - %s
Logged when the Premium feature key was transferred.
0x0180
Information
Premium feature serial number %s
Logged when displaying the Premium feature serial number.
0x0181
Warning
Premium feature serial number
mismatched. Key-vault serial num -
%s
Logged when Premium feature serial number mismatched.
0x0182
Warning
Battery cannot support data
retention for more than %d hours.
Please replace the battery
Logged during the Battery monitoring and it displays the
remaining data retention time of the battery.
0x0183
Information
%s power policy changed to %s
(from %s)
Logged when the power policy of an LD is changed.
0x0184
Warning
%s cannot transition to max power
savings
Logged when LD cannot transition to max power savings.
0x0185
Information
Host driver is loaded and operational This event is not reported to the user.
0x0186
Information
%s mirror broken
Logged when the mirror is broken for an LD.
0x0187
Information
%s mirror joined
Logged when joining the LD with its broken mirror.
0x0188
Warning
%s link %d failure in wide port
This event is not reported to the user.
0x0189
Information
%s link %d restored in wide port
This event is not reported to the user.
0x018a
Information
Memory module FRU is %s
This event is not reported to the user.
0x018b
Warning
Cache-vault power pack is
sub-optimal. Please replace the pack
This event is not reported to the user.
0x018c
Warning
Foreign configuration auto-import
did not import any drives
Logged when the Foreign configuration auto-import did not
import any drives.
Number
Severity
Level
Event Text
Generic Conditions when Each Event Occurs
Summary of Contents for ThinkServer RD650
Page 1: ...ThinkServer 12 Gb s MegaRAID SAS Software User Guide ...
Page 417: ......