LSI Corporation
- 367 -
12Gb/s MegaRAID SAS Software User Guide
March 2014
Appendix A: Events and Messages
0x011f
Warning
Foreign import shall result in a
backward incompatible upgrade of
configuration metadata
Currently not used in the firmware.
0x0120
Information
Redundant path restored for PD %s
Logged when new path is added for the physical drives.
0x0121
Warning
Redundant path broken for PD %s
Logged when one path is removed.
0x0122
Information
Redundant enclosure EMM %s
inserted for EMM %s
Logged when an enclosure is added.
0x0123
Information
Redundant enclosure EMM %s
removed for EMM %s
Logged when an enclosure is removed
0x0124
Warning
Patrol Read can't be started, as PDs
are either not ONLINE, or are in a VD
with an active process, or are in an
excluded VD
Logged when none of the disks can start PR.
0x0125
Information
Replace Drive aborted by user on PD
%s and src is PD %s
Logged when Replace is aborted by the user.
0x0126
Critical
Replace Drive aborted on hot spare
%s from %s, as hot spare needed for
rebuild
Logged when Replace is aborted on a Hotspare.
0x0127
Warning
Replace Drive aborted on PD %s
from PD %s, as rebuild required in
the array
Logged when Replace is stopped for a higher priority rebuild
operation on a drive.
0x0128
Fatal
Controller cache discarded for
missing or offline VD %s
When a VD with cached data goes
offline or missing during runtime, the
cache for the VD is discarded.
Because the VD is offline, the cache
cannot be saved.
Logged when pinned cache lines are discarded for a LD.
0x0129
Information
Replace Drive cannot be started as
PD %s is too small for src PD %s
Logged when destination PD is too small for Replace.
0x012a
Information
Replace Drive cannot be started on
PD %s from PD %s, as SAS/SATA is
not supported in an array
Logged when there is a SAS/SATA mixing violation for the
destination PD.
0x012b
Information
Microcode update started on PD %s
Logged when PD Firmware download starts.
0x012c
Information
Microcode update completed on PD
%s
Logged when PD Firmware download completes.
0x012d
Warning
Microcode update timeout on PD %s Logged when PD Firmware download does not complete
and times out.
0x012e
Warning
Microcode update failed on PD %s
Logged when PD Firmware download fails.
0x012f
Information
Controller properties changed
Logged when any of the controller properties has changed.
0x0130
Information
Patrol Read properties changed
Currently not logged in the firmware.
0x0131
Information
CC Schedule properties changed
Logged when consistency check scheduling property has
changed.
0x0132
Information
Battery properties changed
Logged when any of the BBU properties has changed.
0x0133
Warning
Periodic Battery Relearn is pending.
Please initiate manual learn cycle as
Automatic learn is not enabled
Logged when BBU periodic relearn is pending.
0x0134
Information
Drive security key created
Logged when controller lock key is created.
0x0135
Information
Drive security key backed up
Logged when controller lock key is backed up.
Number
Severity
Level
Event Text
Generic Conditions when Each Event Occurs
Summary of Contents for ThinkServer RD650
Page 1: ...ThinkServer 12 Gb s MegaRAID SAS Software User Guide ...
Page 417: ......
Page 418: ......