Chapter 6: StorCLI
Working with the Storage Command Line Tool
Table 40 Set CC Input Options
Input example:
storcli /c0 set CC=on starttime=2012/02/21 00 excludevd v0-v3
storcli /c
x
show cc
This command shows the consistency check schedule properties for a controller.
Input example:
storcli /c0 show cc
storcli /c
x
show ccrate
This command checks the status of a consistency check operation. The CC rate appears in percentage.
Input example:
storcli /c0 show ccrate
NOTE
A high CC rate slows I/O processing.
6.6.2.4
Premium Feature Key Commands
The Storage Command Line Tool supports the following commands for premium feature keys:
storcli /c
x
set advancedsoftwareoptions(aso) key=<
value
> [preview]
storcli /c
x
aso [transfertovault][rehostcomplete][deactivatetrialkey]
storcli /c
x
show safeid
The detailed description for the command follows.
storcli /c
x
set advancedsoftwareoptions(aso) key=<
value
> [preview]
This command activates advanced software options (ASO) for a controller. You can use the following options with the
advanced software options command.
Option
Value Range
Description
cc
seq
: Sequential mode.
conc
: Concurrent mode.
off
: Turns off the consistency
check.
Sets CC to either sequential mode, or concurrent mode, or turns off the CC.
NOTE
The concurrent mode slows I/O processing.
delay
-1
and any integer value.
Delay a scheduled consistency check. The value is in hours. A value of
0
makes the CC runs continuously with no delay (in a loop).
NOTE
Only scheduled consistency checks can be delayed.
starttime
A valid date and hour in
24-hours format.
Start time of a consistency check is
yyyy/mm/dd hh
format.
excludevd
The range should be less than
the number of virtual drives.
Excludes virtual drives from the consistency checks. To exclude particular
virtual drives, you can provide list of virtual drive names (V
x
,V
y
… format) or
the range of virtual drives that you want to exclude from a consistency
check (V
x
-V
y
format). If this option is not specified in the command, no
virtual drives are excluded.