LSI Corporation
- 140 -
12Gb/s MegaRAID SAS Software User Guide
March 2014
Chapter 5: The HII Configuration Utility
Managing Physical Drives
Table 30 Virtual Drive Policies
5.6
Managing Physical Drives
When you select
Drive Management
on the
Main Menu
, the
Drive Management Selection
dialog appears.
The menu lists all the physical drives that are connected to the controller. Highlight the drive you want to manage and
press Enter. The following dialog appears.
Property
Description
Access
The access policy for the virtual drive. The options are
Read/Write
,
Read Only
, and
Blocked
.
Current Write Cache
Policy
Displays the current write cache policy. The possible values are as follows:
Write-through
(
WThru
): The controller sends a data transfer completion signal to the host when
the virtual drive has received all of the data and has completed the write transaction to the drive.
Write-back
(
WBack
): The controller sends a data transfer completion signal to the host when the
controller cache has received all of the data in a drive write transaction. Data is written to the virtual
drive in accordance with policies set up by the controller. These policies include the amount of dirty
and clean cache lines, the number of cache lines available, and the elapsed time from the last
cache flush.
Force Write Back
.
Default Write Cache
Policy
Displays the default write cache policy of the virtual drive.
Disable Background
Initialization (BGI)
Specifies whether background initialization is enabled or disabled. When BGI is enabled, the firmware
runs the initialization process in the background. When BGI is disabled, the initialization process does
not start automatically and does not run in the background.
Read Cache Policy
The read cache policy for the virtual drive. The possible values are as follows:
Ahead
: The controller reads sequentially ahead of requested data and stores the additional data in
cache memory, anticipating that the data will be needed soon. This process speeds up reads for
sequential data, but provides little improvement when accessing random data.
Normal
: Read-ahead capability is disabled.
Drive Cache
The disk cache policy for the virtual drive. The possible values are
Unchanged
,
Enable
, and
Disable
.
Input/Output (I/O)
The I/O policy for the virtual drive. The possible values are as follows:
Direct
: Data reads are not buffered in cache memory. Data is transferred to the cache and the host
concurrently. If the same data block is read again, it comes from cache memory. (The I/O policy
applies to reads on a specific virtual drive. It does not affect the read- ahead cache.)
Cached
: All reads are buffered in cache.
Summary of Contents for ThinkServer RD650
Page 1: ...ThinkServer 12 Gb s MegaRAID SAS Software User Guide ...
Page 417: ......
Page 418: ......