LSI Corporation
- 360 -
12Gb/s MegaRAID SAS Software User Guide
March 2014
Appendix A: Events and Messages
0x0071
Warning
Unexpected sense: %s, CDB%s,
Sense: %s
Logged when an I/O fails due to unexpected reasons and
sense data needs to be logged.
0x0072
Information
State change on %s from %s to %s
Logged when the state of a drive is changed by the firmware
or by you.
0x0073
Information
State change by user on %s from %s
to %s
Not logged by the firmware.
0x0074
Warning
Redundant path to %s broken
Not logged by the firmware.
0x0075
Information
Redundant path to %s restored
Not logged by the firmware
0x0076
Information
Dedicated Hot Spare Drive %s no
longer useful due to deleted drive
group
Not logged by the firmware.
0x0077
Critical
SAS topology error: Loop detected
Logged when device discovery fails for a SAS device as a loop
was detected.
0x0078
Critical
SAS topology error: Unaddressable
device
Logged when device discovery fails for a SAS device as an
unaddressable device was found.
0x0079
Critical
SAS topology error: Multiple ports to
the same SAS address
Logged when device discovery fails for a SAS device multiple
ports with same SAS address were detected.
0x007a
Critical
SAS topology error: Expander error
Not logged by the firmware.
0x007b
Critical
SAS topology error: SMP timeout
Logged when device discovery fails for a SAS device due to
SMP timeout.
0x007c
Critical
SAS topology error: Out of route
entries
Logged when device discovery fails for a SAS device as
expander route table is out of entries.
0x007d
Critical
SAS topology error: Index not found Logged when device discovery fails for a SAS device as
expander route table out of entries.
0x007e
Critical
SAS topology error: SMP function
failed
Logged when device discovery fails for a SAS device due to
SMP function failure.
0x007f
Critical
SAS topology error: SMP CRC error
Logged when device discovery fails for a SAS device due to
SMP CRC error.
0x0080
Critical
SAS topology error: Multiple
subtractive
Logged when device discovery fails for a SAS device as a
subtractive-to-subtractive link was detected.
0x0081
Critical
SAS topology error: Table to table
Logged when device discovery fails for a SAS device as
table-to-table link was detected.
0x0082
Critical
SAS topology error: Multiple paths
Not logged by the firmware.
0x0083
Fatal
Unable to access device %s
Logged when the inserted drive is bad and unusable.
0x0084
Information
Dedicated Hot Spare created on %s
(%s)
Logged when a drive is configured as a dedicated spare.
0x0085
Information
Dedicated Hot Spare %s disabled
Logged when a drive is removes as a dedicated spare.
0x0086
Critical
Dedicated Hot Spare %s no longer
useful for all drive groups
Logged when an array with a dedicated spare is resized. The
hot spare (dedicated to this array and possibly others) will
not be applicable to other arrays.
0x0087
Information
Global Hot Spare created on %s (%s) Logged when a drive is configured as a global hot spare.
0x0088
Information
Global Hot Spare %s disabled
Logged when a drive configured as global host spare fails or
is unconfigured by you.
0x0089
Critical
Global Hot Spare does not cover all
drive groups
Logged when the global hotspare is too small (or doesn't
meet the SAS/SATA restricitons) to cover certain arrays.
0x008a
Information
Created %s}
Logged as soon as the new logical drive created is added to
the firmware configuration.