LSI Corporation
- 153 -
12Gb/s MegaRAID SAS Software User Guide
March 2014
Chapter 5: The HII Configuration Utility
Managing Hardware Components
Table 34 Advanced Battery Management Properties
5.7.1.1
Setting Automatic Learn Cycle Properties
The
Set Automatic Learn Cycle Properties
dialog appears when you select
Set Automatic Learn Cycle Properties
on the
Advanced Battery Management
dialog.
The small red arrow at the bottom of the dialog indicates that you can scroll down to view more options.
NOTE
The red arrow appears when there is too much information to display
in one dialog. The amount of information that can be displayed in one
dialog depends on the capabilities of the HII browser.
To generate an event as a reminder to start a learn cycle manually, highlight the field next to
Generate an event...
,
and press the spacebar.
To enable or disable automatic learn cycle mode, highlight the field next to
Learn Cycle
, press Enter, and make a
selection from the pop-up menu.
The
Day
,
Time
,
No. of Days
, and
No. of Hours
fields are also user-selectable through popup menus. The
Next Learn
Cycle Time
field shows the time of the next learn cycle.
Use the
Apply
,
OK
, and
Cancel
fields at the bottom of the selections (not visible in this figure) to apply, confirm or
cancel any changes to the learn cycle options.
5.7.2
Managing Enclosures
To manage enclosures and view enclosure properties, select
Enclosure Management
from the
Advanced Hardware
Components
menu.
The
Enclosure Management
dialog shows the firmware version and field replacement unit (FRU) number for the
selected enclosure. To select a different enclosure, highlight the
Select Enclosure
field, press Enter, and select the
enclosure from the pop-up menu.
To view a pop-up menu of drives connected to the enclosure, highlight the
Attached Drives
field and press Enter.
Property
Description
Start Manual Learn Cycle*
Highlight this field and press Enter to start a manual battery learn cycle.
Set Automatic Learn Cycle
Properties*
Highlight this field and press Enter to set the properties for an automatic battery learn cycle.
Manufacturer
Manufacturer of the battery.
Serial Number
Serial number of the battery.
Date of Manufacture
Manufacturing date of the battery.
Firmware Version
Firmware version of the battery.
Status
Status of the battery. If the status is Learning, Degraded, or Failed, a reason is listed for the status.
Voltage
Voltage level of the battery, in mV. Also indicates if the current battery voltage is normal or low.
Current
Current of the battery, in mA.
Design Capacity
Theoretical capacity of the battery.
Full Capacity
Full charge capacity of the battery.
Remaining Capacity
Remaining capacity of the battery.
Auto-learn Mode
Indicates whether auto-learn mode is enabled or disabled. A learn cycle is a battery calibration
operation that the controller performed periodically to determine the battery condition. This
operation cannot be disabled.
Next Learn Cycle Time
Date and hour of the next scheduled learn cycle.