Appendix A: Events and Messages
0x008b
Information
Deleted %s}
Logged when the firmware removes an LD from it's
configuration upon a user request from the applications.
0x008c
Information
Marking LD %s inconsistent due to
active writes at shutdown
Logged when we have active writes on one of the target
disks of a Raid 5 LD at the time of shutdown.
0x008d
Information
Battery Present
Logged during firmware initialization when we check if there
is a battery present and the check turns out true. This event is
also logged when a battery is inserted or replaced with a new
one and the battery present check returns true.
0x008e
Warning
Battery Not Present
Logged if the user has not disabled "Battery Not Present"
warning at the boot time or if a battery has been removed.
0x008f
Information
New Battery Detected
Logged when we have a subsequent boot after a new battery
has been inserted.
0x0090
Information
Battery has been replaced
Logged when a new battery has been replaced with an old
battery.
0x0091
Critical
Battery temperature is high
Logged when we detect that the battery temperature is high
during the periodic battery status check.
0x0092
Warning
Battery voltage low
Not logged by the firmware.
0x0093
Information
Battery started charging
Logged as part of monitoring the battery status when the
battery is getting charged.
0x0094
Information
Battery is discharging
Logged as part of monitoring the battery status when the
battery is getting discharged.
0x0095
Information
Battery temperature is normal
Logged as part of monitoring the battery status when the
temperature of the battery is normal.
0x0096
Fatal
Battery has failed and cannot
support data retention. Please
replace the battery.
Logged when there is not enough capacity left in battery for
expected data retention time. Battery has to be replaced.
0x0097
Information
Battery relearn started
logged when the battery relearn started, initiated either by
the user or automatically.
0x0098
Information
Battery relearn in progress
Logged as part of monitoring the battery status when the
battery relearn is in progress.
0x0099
Information
Battery relearn completed
Logged as part of monitoring the battery status when the
battery relearn is complete.
0x009a
Critical
Battery relearn timed out
Not logged by the firmware.
0x009b
Information
Battery relearn pending: Battery is
under charge
Logged as part of monitoring the battery status when the
battery relearn is requested but yet to start.
0x009c
Information
Battery relearn postponed
Logged as part of monitoring the battery status when the
battery relearn is requested but postponed as there is valid
pinned cache present. This event can also be logged when
learn delay interval has been explicitly set.
0x009d
Information
Battery relearn will start in 4 days
Logged as part of providing battery learn cycle information
when auto learn is enabled.
0x009e
Information
Battery relearn will start in 2 day
Logged as part of providing battery learn cycle information
when auto learn is enabled.
0x009f
Information
Battery relearn will start in 1 day
Logged as part of providing battery learn cycle information
when auto learn is enabled.
0x00a0
Information
Battery relearn will start in 5 hours
Logged as part of providing battery learn cycle information
when auto learn is enabled.
0x00a1
Information
Battery removed
Logged as part of periodic monitoring of the battery status
when a battery has been removed.