LSI Corporation
- 309 -
12Gb/s MegaRAID SAS Software User Guide
March 2014
Chapter 10: Monitoring Controllers and Their Attached Devices
Battery Learn Cycle
Figure 192 Battery Properties
Some fields like
Charge
appear only in the BBU property pages of batteries other than TMM-C battery. Similarly
fields such as
Capacitance
appear only in the BBU property pages of TMM-C battery.
3.
Click
Advanced Properties
to view additional BBU properties
The
Advanced Properties
dialog appears.
Figure 193 Advanced Properties
Additional properties such as
Manufacturer
,
Serial Number
,
Full Capacity
, are displayed. You can also set
battery learn cycles from the
Advanced Properties
dialog. For more details on battery learn cycles, see the
following section.
10.21
Battery Learn Cycle
Learn cycle is a battery calibration operation that is performed by the controller periodically to determine the
condition of the battery. You can start battery learn cycles manually or automatically. To choose automatic battery
learn cycles, enable automatic learn cycles.
If you enable automatic learn cycles, you can delay the start of the learn cycles for up to 168 hours (7 days). If you
select the
Generate an event to remind me when to start a learn cycle manually
check box in the
Set Automatic
Learn Cycle Properties
dialog, the automatic learn cycle gets disabled and an event is generated to remind you when
you need to start a learn cycle.