LSI Corporation
- 273 -
12Gb/s MegaRAID SAS Software User Guide
March 2014
Chapter 9: Configuration
Adding Hot Spare Drives
3.
Click
Next
.
The
Create Virtual Drive - Drive group and Virtual drive settings
dialog appears.
9.2.1
Converting JBOD to Unconfigured Good from the MegaRAID Storage Manager Main Menu
You can also convert JBOD to Unconfigured Good by performing these steps:
1.
Select
Controller >Make UnConfigured Good
from the main
MegaRAID Storage Manager
main menu.
The
Make Configured Good
dialog appears, as shown in the following figure.
Figure 164 Make Configured Good Dialog
2.
Select the JBOD drives to be configured as unconfigured good.
3.
Click
OK
.
The selected JBOD drives are configured as unconfigured good.
9.3
Adding Hot Spare Drives
Hot spares are drives that are available to automatically replace failed drives in a RAID 1, RAID 5, RAID 6, RAID 10,
RAID 50, or RAID 60 virtual drive.
Dedicated hot spares
can be used to replace failed drives in a selected drive group
only.
Global hot spares
are available to any virtual drive on a specific controller.
To add a dedicated or global hot spare drive, follow these steps:
1.
Select the
Physical
tab in the left panel of the MegaRAID Storage Manager main menu, and click the icon of an
unused drive.
For each drive, the window displays the port number, enclosure number, slot number, drive state, drive capacity,
and drive manufacturer.
2.
Either select
Go To > Physical Drive > Assign Global Hot Spare
, or select
Go To > Physical Drive > Assign
Dedicated Hot Spare
.
Summary of Contents for ThinkServer RD650
Page 1: ...ThinkServer 12 Gb s MegaRAID SAS Software User Guide ...
Page 417: ......
Page 418: ......