LSI Corporation
- 392 -
12Gb/s MegaRAID SAS Software User Guide
March 2014
Appendix C: MegaCLI Commands to StorCLI Command Conversion
Battery Commands
C.6
Security Commands
Table 75 Security Commands
C.7
Virtual Drive Commands
Table 76 Virtual Drive Commands
Description
MegaCLI Command
StorCLI Command
Set the key ID for the controller.
MegaCli -CreateSecurityKey
-SecurityKey
sssssssssss
|
[-Passphrase
sssssssssss
]
|[-KeyID
kkkkkkkkkkk
] -aN
storcli /c
x
set
SecurityKey=
XXXXXX
[passphrase=
yyyyy
]
[keyId=
zzzz
]
Change the security key for the
controller.
MegaCli -ChangeSecurityKey
-OldSecurityKey
sssssssssss
| -Secur
ityKey
sssssssssss
|
[-Passphrase
sssssssssss
] | [-keyID
kkkkkkkkkkk
] -aN
storcli /c
x
set
SecurityKey=
XXXXXX
OldSecurityKey=
yyyy
y
Compare and verify the security
key for the controller.
MegaCli -VerifySecurityKey
-SecurityKey
sssssssssss
-aN
storcli /c
x
compare SecurityKey=
xxxxxx
Delete the security key.
MegaCLI -DestroySecurityKey |
[-Force] -aN
storcli /c
x
delete SecurityKey
Set the security key for the
controller.
MegaCli -SetKeyID -KeyID
kkkkkkkkkkk
-aN
storcli /c
x
set SecurityKey KeyId=
xxxx
Description
MegaCLI Command
StorCLI Command
Show the virtual drive
information.
MegaCli –LDInfo –Lx|-L0,1,2|-Lall
-aN|-a0,1,2|-aALL
storcli /c
x
/v(
x
|all) show
storcli /c
x
/v(
x
|all) show all
Set virtual drive properties.
MegaCli –LDSetProp WT | WB|NORA
|RA |
ADRA|-Cached|Direct|CachedBadBBU|
NoCachedBadBBU} | -RW|RO|Blocked |
{-Name nameString}
|-EnDskCache|DisDskCache –Lx|
-L0,1,2|-Lall -aN|-a0,1,2|-aALL
storcli /c
x
/v(
x
|all) set
wrcache=WT|WB|AWB
storcli /c
x
/v(
x
|all) set rdcache=RA|NoRA
storcli /c
x
/v(
x
|all) set
iopolicy=Cached|Direct
storcli /c
x
/v(
x
|all) set
accesspolicy=RW|RO|Blocked|RmvBlkd
storcli /c
x
/v(
x
|all) set
pdcache=On|Off|Default
storcli /c
x
/v(
x
|all) set
name=<
NameString
>
Set power-saving (dimmer
switch) properties.
MegaCli -LDSetPowerPolicy
-Default| -Automatic| -None|
-Maximum| -MaximumWithoutCaching
-Lx|-L0,1,2|-Lall
-aN|-a0,1,2|-aALL
storcli /c
x
/v(
x
|all) set
ds=Default|Auto|None|Max|MaxNoCache
Show virtual drive expansion
information.
MegaCli -getLdExpansionInfo
-Lx|-L0,1,2|-Lall
-aN|-a0,1,2|-aALL
storcli /c
x
/v(
x
|all) show expansion
Expand the virtual drive within
the existing array; also use if
you replace the drives with
larger drives, beyond the size of
the existing array.
MegaCli -LdExpansion -pN
-dontExpandArray -Lx|-L0,1,2|-Lall
-aN|-a0,1,2|-aALL
storcli /c
x
/v(
x
|all) expand Size=<
value
>
[expandarray]
Summary of Contents for ThinkServer RD650
Page 1: ...ThinkServer 12 Gb s MegaRAID SAS Software User Guide ...
Page 417: ......
Page 418: ......