Chapter 5: The HII Configuration Utility
Managing Controllers
—
Disabled
: Patrol read does not run.
2.
To specify a rate for the percentage of system resources dedicated to perform a patrol read operation on
configured drives, highlight
Rate
, specify a rate as a numeric value and press Enter.
100 is the maximum numeric value that you can enter as the rate.
3.
To select a patrol read setting for unconfigured space, highlight
Setting for Unconfigured Space
, and press
Enter. Select either
Enabled
or
Disabled
and press Enter.
4.
Highlight
Apply Changes
and press Enter. The new settings are saved in the controller properties.
To start a patrol read without changing the patrol read properties, follow these steps:
1.
Highlight Start in the
Patrol Read
dialog and press Enter.
2.
A message box appears stating that the operation has been successful. Click OK to return to the
Patrol Read
dialog.
Suspend
and
Stop
are now active.
5.4.12
Changing Power Save Settings
The following dialog appears when you select
Power Save Settings
from the
Advanced Controller Properties
dialog.
Figure 90 Power Save Settings
The above dialog lets you choose if you want unconfigured drives, hot spares, and configured drives to enter the
power-save mode. When the unconfigured drives, hot spares, and configured drives are in power-save mode, they can
be spun down.
Follow these steps to change the power-save settings:
NOTE
You can only view the properties/options supported by your
controller.
1.
To enable or disable spinning down of unconfigured good drives, highlight
Spin Down Unconfigured Good
and
press Enter. Select
Enable
or
Disable
and press Enter.
2.
To enable or disable spinning down of hot spares, highlight
Spin Down Hot Spare Drives
and press Enter.
Enable
or
Disable
and press Enter.