Sierra M6
‐
2 SAS/SATA Protocol Analyzer User Manual
77
Trigger Setup
LeCroy Corporation
ATA Command
Double
‐
click ATA Command in the Pattern window to open the ATA Command Pattern
dialog.
Figure 2.47: SAS: FIS Pattern Dialog
SAS
vs.
SATA:
SATA Dialog has different dropdown options.
Click the down arrow next to the Command dropdown list, scroll the list to choose a
command to trigger on, and click OK.
A powerful triggering choice is
Any
Command
, which causes the analyzer to trigger on
any ATA command.