Sierra M6
‐
2 SAS/SATA Protocol Analyzer User Manual
159
Performance Analysis
LeCroy Corporation
Note:
When you use the Exerciser, channel 2 is not usable and is greyed out.
Figure 2.163: SATA: Settings Dialog
The settings dialog allows you to set the Analysis update interval and define the counter
mode.
1. Choose the
Update
Interval
in the range of 1 ms to 245 minutes.
2. Set the
Counter
Mode
to either Cumulative or Instantaneous.
Cumulative causes the measurement counters to continually increment>
Instantaneous causes the measurement counters to reset for each Update interval.
3. Set the
Analyzer
Speed
for each port used.
4. To disable descrambling, check the
Disable
Descrambling
check box or check
Disable
Scrambling
.
5. Enter a value for
Primitive
Response
Timeout
.
6. Choose the
Align
Transmission
Period
by checking the corresponding option button.
7. To select
Protocol
Errors
to exclude from the analysis, click the
Protocol
Error
Mask
button and check any or all of the protocol errors to exclude. See
8. To save the analysis result for later review, check
Save
to
file
and enter the path in
which to save the result.
9. To include a descriptive note about the project, click the
Notes
tab and enter
information in the
Notes
“Add a Project Note” on page 100
.