LeCroy Corporation
Advanced Mode (User
‐
Defined)
104
Sierra M6
‐
2 SAS/SATA Protocol Analyzer User Manual
State Number for Complex Trigger Sequences
To follow the path of complex trigger sequences, you can display state number.
To see state number, in Packet View right
‐
click a link layer packet, show field, and select
state number.
Setting Trigger Conditions
To set the If and Else If trigger condition:
1. Click the
Add
Pattern
button
for a Pattern field and choose a trigger condition
from the drop
‐
down list.
Figure 2.78: SAS: Choosing a Trigger Condition
2. Define each selected pattern in the same way as in Easy Mode, as described starting
on page 59. To use a timer, define it first.
Note:
You can set a timer for any If or Else If condition.
3. Enter a value for the number of occurrences before trigger in the
Cont
field, up to a
maximum of 65535 occurrences.
4. Choose a capture option:
Everything,
Nothing,
or
Pattern
.
5. If you choose Pattern, you can select patterns for inclusion or exclusion. Clicking the
Pattern
option enables a pattern definition dialog.
Figure 2.79: SAS: Choosing a Pattern