LeCroy Corporation
Sierra Trainer Generation Commands
432
Sierra M6
‐
2 SAS/SATA Protocol Analyzer User Manual
SATA
Link
Init
Settings
OOB_SATA_D102_Time
100000
D10.2 time for SATA link synchronization in
OOBIs.During the specified period, the generator will
transmit D10.2 symbols.
OOB_SATA_Align_Time
100000
ALIGN(0) time for SATA link synchronization in
OOBIs.During the specified period, the generator will
transmit ALIGN(0) primitives.
SAS
Speed
Negotiation
Settings
OOB_SAS_Align1_Time
81920
ALIGN(1) time for SAS speed negotiation in
OOBIs.During the specified period, the generator will
transmit ALIGN(1) primitives.
OOB_SAS_Align0_Time
81920
ALIGN(0) time for SAS speed negotiation in
OOBIs.During the specified period, the generator will
transmit ALIGN(0) primitives.
OOB_SAS_Interspeed_Time 750000
Interspeed time for SAS speed negotiation in
OOBIs.During the specified period, the generator will
keep the line at electric idle.
OOB_SpeedNeg_MTT.
29998080
OOBI
The maximum time in OOBI during which training
phase of speed negotiation should be completed in
Train
‐
SNW.
OOB_SpeedNeg_SNTT.
2200
OOBI
The time in OOBI during which generator transmits
phy capability bits in SNW
‐
3. In Automatic
connection This value is also used for the time during
which generator sends Align0 and Align1 in SNW1
and SNW2.
OOB_SpeedNeg_BCT.
2200
OOBI
The time in OOBI during which generator transmits
COMWAKE or D.C. idle during SNW
‐
3.
Setting
Default
Value
Description