KUNBUS-COM EtherCAT
79 / 135
0x1401 Input SDI
Modbus Register
0x1401-0x1501
Coil Address
0x2001 – 0x4000
Value Range
0x00-0xff
Initial value
0x00
Number of bytes available
512
Permanently stored
No
Access
Read/Write
0x1801 Input Fieldbus
Modbus Register
0x1801-0x1880
Coil Address
0x4001 – 0x6001
Value Range
-
Initial value
0x00
Number of bytes available
256
Permanently stored
No
Access
Read Only
0x1c01 Input DPR
You can only read this register if the COMS-Modul is in DPR mode.
If the COMS-Modul is not running in DPR mode, selecting this
register as a source register for a mapping entry will result in an
error.
Modbus Register
0x1c01-0x1d01
Coil Address
0x6001 …
Value Range
-
Initial value
0x00
Number of bytes available
0-512 (configurable)
Permanently stored
No
Access
Read Only
0x2001 Output SSC
Modbus Register
0x2001-0x2080
Value Range
-
Coil Address
0x8001 – 0x8800
Initial value
0x00
Number of bytes available
256
Permanently stored
No
Access
Read Only
0x2401 Output SDI
Modbus Register
0x2401-0x2501
Coil Address
0xa001 – 0xb000
Value Range
-
Default Value
0x00
Number of bytes available
0-512 (configurable)
Permanently stored
No
Access
Read Only
Memory Register