KUNBUS-COM EtherCAT
128 / 135
SSC SSR Master Mode, configured registers
– You have selected "configured shift registers" as the configuration
source for the SSC.
In this menu you will find the following information:
– Number of shift registers
– Bitrate
If the number of configured registers does not match the number of
connected registers or the shift register chain is not working, you will
see the message "Shift Register Chain not working“.
--------------------------------------------------
KUNBUS-
COM
- SSC Status
--------------------------------------------------
<cr> = refresh; <Esc> = return
SSC SSR Master Mode, configured shift registers
Actual Number of Input registers: 1/1
Actual Number of Output registers: 1/1
Actual Bitrate: 4800 kBit/s
--------------------------------------------------
>
SSC SSR Master Mode, disabled
You will find this representation if the SSC Master was switched off
via the menu.
--------------------------------------------------
KUNBUS-
COM
- SSC Status
--------------------------------------------------
<cr> = refresh; <Esc> = return
SSC SSR Master Mode, disabled
--------------------------------------------------
>
SSC SPI Slave Mode
– You have selected "SSC SPI Slave Mode" as the configuration source.
In this menu you will find information about clock and data level.
--------------------------------------------------
KUNBUS-
COM
- SSC Status
--------------------------------------------------
<cr> = refresh; <Esc> = return
SSC SPI Slave Mode
Actual SPI Settings: Polarity Normal, Falling Edge, CLK High, MSB
first
--------------------------------------------------
>
CDI