KUNBUS-COM EtherCAT
115 / 135
--------------------------------------------------
KUNBUS-
COM
– Set Arbitray Register
--------------------------------------------------
Register Number: 0x0013
Current Value : 1 0x0001 0000_0000_0000_0001b
Enter New Value: 2
New Value Set : 2 0x0002 0000_0000_0000_0010b
Register Number:
The configuration interface detects whether it is a decimal,
hexadecimal or binary value based on the notation and displays the
saved value once again for confirmation.
CAUTION
Please note that some settings could lead to functional incapacity of
the CDI interface.
You can only remedy such an inaccurate setting with a functional SDI or
DPR interface.
Ø
When correcting the error, all settings made previously are reset.
è
Write the value 0x0002 in the register 0x0001
ð
You have set the module to the original settings. The CDI interface is
now available again.
2.13 Script Interpreter
In this menu you have the option, to activate or deactivate a script
and to select the desired port.
NOTICE
Please note that activation of a script influences the individual port.
Never activate a script with the setting "Port used by script: CDI" if you do
not have any other fully functional access (SDI, DPR) to the parameter
memory registers except via the CDI interface! In such a case, your module
is no longer configurable! You can switch the status between disabled and
enabled by entering [1]+[Return].
– You can define the SDI or CDI as port. You switch between both
options by entering [2]+[Return].
--------------------------------------------------
KUNBUS-
COM
- Script Interpreter
--------------------------------------------------
1 - State: disabled
2 - Port used by script: SDI
--------------------------------------------------
>
2.14 Reset Module
With this option you can restart the module. All changes that you
have set will be activated in the operating mode after a restart. The
fieldbus connection is interrupted during the restart.
CDI