KUNBUS-COM EtherCAT
25 / 135
◦ Open the main menu of the CDI as described in the Appendix "Setting
up a serial connection using PuTTY".
Main Menu
The main menu is your access point for operating the module using
the CDI. After a reset, the module transmits this main menu to the
terminal.
--------------------------------------------------
KUNBUS-
COM
– Main Menu
--------------------------------------------------
1 – Module Information
2 – Interface Configuration
3 - Monitor Communication
4 – Module Status
--------------------------------------------------
>
Configuration menu
◦ In the main menu enter [2]+[Return].
ð
You will be taken to the configuration menu "2-Interface Configuration"
In this menu you have the option to set the mapping for the data
broker and the operational parameters for the different interfaces.
– Select "Fieldbus Output Mapping" to define the data source for the
fieldbus output register.
--------------------------------------------------
KUNBUS-
COM
– Interface Configuration
--------------------------------------------------
Operating Mode: Config
1 - SDI Communication
2 - CDI Communication
3 - SSC Communication
4 - DPR Configuration
6 - SDI Output mapping
7 - SSC Output mapping
8 - Fieldbus Output mapping
9 - DPR Output mapping
11 - Fieldbus Specific
12 - Set Arbitrary Register
13 - Script Interpreter
14 - Reset Module
15 - Reset to Factory Settings
16 - Extended Mapping
--------------------------------------------------
>
Components