406388/F
241
Description
Each screen capture you make is saved in
.jpg
format on the computer hard disk. The
file name reflects the current date and time. In the image folder, use the operating system
functionality to delete, copy or rename the screen capture files.
Note
You can make different screen captures depending on your operational requirements.
• Select
Screen Capture
to make a screen dump of the current display presentation.
• To save an instantaneous image of the current frequency spectrum, select
Screen
Captures
in the
Spectrum
dialog box.
Related topics
Accessing the saved data files, page 164
Saving a sensor screen capture, page 158
Accessing the screen capture images to delete, move or copy them, page 159
Calibration dialog box
The purpose of the
Calibration
dialog box is to accept and apply the calibration
information from the depth sensor calibration.
How to open
This function is opened from the
Setup
menu.
Description
In order to provide correct and accurate readings, the depth measurement must be
calibrated. The sensor detects the depth using water pressure measurements. Only depth
measurement can be calibrated.
You can currently calibrate the depth measurement for sensors interfacing PI50 or PI60
Receiver Units.
Related topics
Calibrating the depth measurement, page 154
(Pitch and Roll) Calibration dialog box, page 276
Manually entering the calibration values for the pitch and roll measurements, page 156