Observe the numerical presentation of the sensor depth, and allow the reading
to stabilize itself.
5
On the
Setup
menu, select
Calibration
.
6
Select the input system from the available list.
7
Select
Start Calibration.
8
Wait for the system to do the calibration.
The dialog box will close when the calibration process is finished.
9
Observe the numerical presentation of the sensor depth, and verify that it reads
1 meter.
10
Select
Close
to save the chosen settings and close the dialog box.
11
Retrieve the sensor from the water.
Related topics
Calibration dialog box, page 241
(Pitch and Roll) Calibration dialog box, page 276
Manually entering the calibration values for the pitch and roll measurements, page 156
Performing a first time calibration of the roll and pitch
measurements of a door mounted sensor
If you want your sensor to measure the pitch and roll of the trawl doors, you must
calibrate it. You can calibrate a sensor in the relevant
Configurator
dialog box.
Prerequisites
Calibration must be done with the sensor mounted in its installation adapter on the
trawl door(s).
Context
When a sensor is mounted on a trawl door, the pitch and roll measurements may need to
be calibrated. If you do not calibrate your sensors you will not know if the pitch and
roll readings are correct. If existing sensors have been replaced, or new sensors have
been installed, a new calibration is required if the trawl door installation offset values are
not available.
Procedure
1
Place the sensor in the door adapter.
On the port door, the “down element shall face down”. On the starboard door, the
“side” element shall face down.
2
Place the door on a stable surface.