![Kongsberg Seatex Seapath 200 Installation Manual Download Page 34](http://html.mh-extra.com/html/kongsberg/seatex-seapath-200/seatex-seapath-200_installation-manual_1992649034.webp)
Seatex Seapath 200 Installation Manual, rev. 13
Installation
20
3.4.2.1
MRU to Processing Unit cable wiring
The MRU can be connected to the Processing Unit in the following three ways:
•
A cable with the MRU connector in one end and a DB-15 male connector for the
Processing Unit in the other end.
•
A cable that is terminated in the MRU junction box in one end and with a DB-15 male
connector for the Processing Unit in the other end.
•
A cable that is terminated in the MRU junction box in one end and terminated in the
Processing Unit connection box in the other end.
For the first two alternatives the cable wiring is as follows:
Processing Unit
Signal
Pair no.
MRU junct. box
MRU connector
Pin no.
Colour
Pin no.
Pin no.
1
screen
chassis (x3 side)
A
7
PGND
1 blue
2 (x1 side)
B
14
+24 V
1 white
1 (x1 side)
R
2
TX+
2 white
3 (x1 side)
C
9
TX-
2 blue
4 (x1 side)
T
3
RX+
3 white
5 (x1 side)
S
10
RX-
3 blue
6 (x1 side)
P
11
XIN
4 white
23 (x1 side)
U
5
LGND
4 blue
24 (x1 side)
a
For the last alternative with termination in the MRU junction box in one end and termination
in the Processing Unit connection box in the other end, the cable wiring is as follows:
Processing Unit
Signal
Pair no.
PU connection box
MRU junct. box
Pin no.
Colour
Pin no.
Pin no.
1
screen
9
chassis (x3 side)
7
PGND
1 blue
2
2 (x1 side)
14
+24 V
1 red
1
1 (x1 side)
2
TX+
2 yellow
3
3 (x1 side)
9
TX-
2 green
4
4 (x1 side)
3
RX+
3 pink
5
5 (x1 side)
10
RX-
3 grey
6
6 (x1 side)
11
XIN
4 brown
7
23 (x1 side)
5
LGND
4 white
8
24 (x1 side)
The MRU is supplied with 24 VDC power from the MRU port on the Processing Unit.
Note
The shield around each pair in the cable has to be individually isolated in the DB-
15 connector. The outer shield is connected to pin 1 (screen) in this connector,
which is an open end (not connected to earth). In the MRU junction box both the
shield around each pair and the outer shield are terminated in pin 1 (chassis) on
the x3 side.
Summary of Contents for Seatex Seapath 200
Page 1: ...Seatex Seapath 200 Installation Manual Issued 2008 06 09 ...
Page 2: ...Blank page ...
Page 4: ...IV Blank page ...
Page 6: ...VI Blank page ...
Page 10: ...X Blank page ...
Page 14: ...XIV Blank page ...
Page 18: ...Seatex Seapath 200 Installation Manual rev 13 Introduction 4 Blank page ...
Page 22: ...Seatex Seapath 200 Installation Manual rev 13 Specifications 8 Blank page ...
Page 53: ...Seatex Seapath 200 Installation Manual rev 13 Installation drawings 39 ...
Page 54: ...Seatex Seapath 200 Installation Manual rev 13 Installation drawings 40 ...
Page 55: ...Seatex Seapath 200 Installation Manual rev 13 Installation drawings 41 ...
Page 56: ...Seatex Seapath 200 Installation Manual rev 13 Installation drawings 42 ...
Page 64: ...Seatex Seapath 200 Installation Manual rev 13 Appendix A Installation worksheet 50 Blank page ...
Page 80: ...Seatex Seapath 200 Installation Manual rev 13 Appendix C Installation of coax connectors 66 ...
Page 81: ...Seatex Seapath 200 Installation Manual rev 13 Appendix C Installation of coax connectors 67 ...
Page 82: ...Seatex Seapath 200 Installation Manual rev 13 Appendix C Installation of coax connectors 68 ...
Page 83: ...Seatex Seapath 200 Installation Manual rev 13 Appendix C Installation of coax connectors 69 ...