Seatex Seapath 200 Installation Manual, rev. 13
Specifications
7
Max. allowed vibration non-operational (0-2000 Hz continuous): .................................. 20 m/s
2
Max. shock non-operational (10 ms peak): .................................................................. 1000 m/s
2
MRU Junction Box, MRU-E-JB1
Material: ..................................................................................................................... Aluminium
Enclosure protection: .......................................................................................................... IP-65
GPS Antennas (L1)
Enclosure material: ..................................................................................... Weatherable Polymer
Operating temperature range: ................................................................................... -40 to +70ºC
Operating humidity (max.): ................................................................................................. 100%
2.4
Cable
Cable MRU-E-CS1
Type: ...................................... Heavy Duty Screened, Habia Aquatherm RTFR 14x2x0.25 mm
2
Length: ................................................................................................................................... 3 m
Diameter: ........................................................................................................................ 13.5 mm
Flame retardation: ........................................................................................................ IEC 332-1
Insulation: ............................................................................................................................ ETFE
Screen: ............................................................................................................................ Cu-braid
Processing Unit to MRU Junction Box Cable
Type: ........................................................................................................ LAMAC 4x2x0.5 mm
2
Maximum length: ............................................................................................................... 100 m
Diameter: ........................................................................................................................... 10 mm
Flame retardation: .................................................................................................... IEC 332-3/A
The GPS Antenna Cables (Coax)
Type: ................................................................................................... NK ½"-Superflex 50 BHF
Attenuation: ........................................................................................ 14 dB/100 m (at 1.6 GHz)
Maximum length (each cable): ........................................................................................... 100 m
Diameter: ........................................................................................................................ 13.2 mm
Minimum bend radius: ...................................................................................................... 32 mm
Flame retardation: ........................................................... CATV, UL1581, IEC 332-3, IEEE383
Coax connectors: .............................................................................. Huber+Suhner 11 N-50-9-9
Summary of Contents for Seatex Seapath 200
Page 1: ...Seatex Seapath 200 Installation Manual Issued 2008 06 09 ...
Page 2: ...Blank page ...
Page 4: ...IV Blank page ...
Page 6: ...VI Blank page ...
Page 10: ...X Blank page ...
Page 14: ...XIV Blank page ...
Page 18: ...Seatex Seapath 200 Installation Manual rev 13 Introduction 4 Blank page ...
Page 22: ...Seatex Seapath 200 Installation Manual rev 13 Specifications 8 Blank page ...
Page 53: ...Seatex Seapath 200 Installation Manual rev 13 Installation drawings 39 ...
Page 54: ...Seatex Seapath 200 Installation Manual rev 13 Installation drawings 40 ...
Page 55: ...Seatex Seapath 200 Installation Manual rev 13 Installation drawings 41 ...
Page 56: ...Seatex Seapath 200 Installation Manual rev 13 Installation drawings 42 ...
Page 64: ...Seatex Seapath 200 Installation Manual rev 13 Appendix A Installation worksheet 50 Blank page ...
Page 80: ...Seatex Seapath 200 Installation Manual rev 13 Appendix C Installation of coax connectors 66 ...
Page 81: ...Seatex Seapath 200 Installation Manual rev 13 Appendix C Installation of coax connectors 67 ...
Page 82: ...Seatex Seapath 200 Installation Manual rev 13 Appendix C Installation of coax connectors 68 ...
Page 83: ...Seatex Seapath 200 Installation Manual rev 13 Appendix C Installation of coax connectors 69 ...