4.
Operate each work equipment control lever and attach-
ment control pedal fully to the front, rear, right, and left for
2 to 3 times within 15 seconds to release the internal pres-
sure in the hydraulic circuit.
5.
Operate the operating portion (g) of the lock lever to set it
to LOCK position (L).
After preparation is completed, replace the additional filter for breaker according to the following procedure.
METHOD FOR REPLACING ADDITIONAL FILTER ELEMENT FOR BREAKER
1.
Loosen the oil filler cap (F) slowly on the top of the hy-
draulic tank to release the internal pressure in the hydraul-
ic tank.
2.
Set a container to catch the oil under the additional filter at
the position pointed with the arrow.
HANDLE MACHINE READY FOR INSTALLATION OF ATTACHMENT
ATTACHMENTS AND OPTIONS
6-28