“SCR Information” screen displays remaining time to the next
Inducement status in the column (5), and information on the
Urea SCR System condition (3), and the current status of In-
ducement (4).
• Warning:
No audible alert.
The DEF system caution lamp (1) lights up in yellow.
Note: Action level “L01” once shows up in yellow on the
machine monitor (2) for two seconds and goes out.
Press F6 to display the “SCR Information” screen.
“SCR Information” screen message (4): “1 Please inspect
and maintain SCR system.”
Move the machine to the safe place and contact your Ko-
matsu distributor.
If operation continues for 5 hours after “Warning” started
without taking any actions instructed by the action level ta-
ble, Inducement advances to “Continuous Warning”.
• Continuous Warning:
The audible alert sounds in repetition of “Triple-beep
alarm”.
The DEF system caution lamp (1) lights up in yellow.
If operation continues for 5 hours after “Warning” started
without taking any actions instructed by the action level ta-
ble, Inducement advances to “Continuous Warning”.
Press F6 to display the “SCR Information” screen.
“SCR Information” screen message (4): “2 Without treat-
ment, engine power will be derated.”
Move the machine to the safe place and contact your Ko-
matsu distributor.
The duration time of “Continuous Warning” is 5 hours. The
remaining time (Hours and Minutes) to “Low level Induce-
ment” is displayed in the column (5) of “SCR Information”
screen.
In “Low level Inducement”, engine power will be derated.
OPERATION
EXPLANATION OF COMPONENTS
3-129
Summary of Contents for HB215LC-3
Page 2: ......
Page 24: ......
Page 27: ...LOCATION OF SAFETY LABELS SAFETY SAFETY LABELS 2 3...
Page 72: ......
Page 344: ......
Page 431: ...SPECIFICATIONS 5 1...
Page 474: ......
Page 475: ...REPLACEMENT PARTS 7 1...
Page 482: ......
Page 491: ......