![Komatsu HB215LC-3 Operation & Maintenance Manual Download Page 204](http://html1.mh-extra.com/html/komatsu/hb215lc-3/hb215lc-3_operation-and-maintenance-manual_1991203204.webp)
“SCR Information” screen message (5): “1 Please inspect
and maintain SCR system.”
Engine power is derated.
Move the machine to the safe place and contact your Ko-
matsu distributor.
If operation continues for 5 hours after “Warning” started
without taking any actions instructed by the action level ta-
ble, Inducement advances to “Continuous Warning”. The
remaining time (Hours and Minutes) to “Continuous Warn-
ing” is displayed in the column (5) of “SCR Information”
screen.
• Continuous Warning:
The audible alert sounds in repetition of “Triple-beep
alarm”.
The engine system caution lamp (1) lights up in red.
The DEF system caution lamp (2) lights up in yellow.
The action level “L03” is displayed in red (3).
Press F6 to display the “SCR Information” screen.
“SCR Information” screen message (5): “2 Without treat-
ment, engine power will be derated.”
Move the machine to the safe place and contact your Ko-
matsu distributor.
The duration time of “Continuous Warning” is 5 hours. The
remaining time (Hours and Minutes) to “Low level Induce-
ment” is displayed in the column (6) of “SCR Information”
screen.
In “Low level Inducement”, engine power will be derated.
• Low level Inducement:
The audible alert sounds in Intermittent alarm.
On the warning display (7), the engine system caution
lamp, DEF system caution lamp, and hybrid caution lamp
light up in red.
The action level “L03” is displayed in red (3).
Press F6 to display the “SCR Information” screen.
“SCR Information” screen message (5): “3 Engine power is
under deration.”
Due to the reduction of engine power, the machine normal
operation will be limited.
The hybrid system output is also limited, and the swing
motor output is limited.
The duration time of “Low level Inducement” is 10 hours.
The remaining time (Hours and Minutes) to “Severe In-
ducement” is displayed in the column (6) of “SCR Informa-
tion” screen.
In “Severe Inducement”, engine power will be derated fur-
ther.
Move the machine to the safe place and contact your Komatsu distributor.
EXPLANATION OF COMPONENTS
OPERATION
3-132
Summary of Contents for HB215LC-3
Page 2: ......
Page 24: ......
Page 27: ...LOCATION OF SAFETY LABELS SAFETY SAFETY LABELS 2 3...
Page 72: ......
Page 344: ......
Page 431: ...SPECIFICATIONS 5 1...
Page 474: ......
Page 475: ...REPLACEMENT PARTS 7 1...
Page 482: ......
Page 491: ......