The aftertreatment devices regeneration display (1) may light
up even if the regeneration disable is set, but the operation of
Regeneration Disable cannot be performed.
When the aftertreatment devices regeneration should be stopped during being
regenerated.
1.
(When the aftertreatment devices regeneration display (1)
is displayed on the standard screen)
When switch F6 is pressed on the standard screen, the
“Aftertreatment Devices Regeneration” screen is dis-
played.
2.
Select the Regeneration Disable and then press the switch
F6, and the regeneration stops.
Regeneration disable may not be performed during regenera-
tion.
PROCEDURE FOR CANCELING AFTERTREATMENT DEVICES REGENERATION
DISABLE
k
k
CAUTION
Move the machine to a safe place for performing restoration of the regeneration.
1.
Set the lock lever to LOCK position, and turn the fuel control dial to Low idle (MIN) position.