RMS compact
41
Once the timer value has been set, enter the FULL PATH to the batchfile into the
Batch File
field (including the
drive letter). In the example above, we have a batchfile that will send a broadcast message to an administrator,
informing the temperature threshold has been breached. The contents of this file might be:
net send administrator Rack over temperature
(for example) This batchfile will run 2 minutes after the alarm has been raised by the RMS compact unit.
Sending an SMS Message
An SMS message is configured, simply by typing a text string into the
SMS Message
field of the action screen,
for example :
Figure 53: SMS Action
Once the Temperature 1 (UCL) alarm has been triggered, the text in the
SMS Message
Field will be sent to the
SMS number configured in the
Configure SMS
menu of the Viewer/Programmer software (see previous
section)
SMS Screen
This screen configures the parameters need to send to send a message (using SMS) to a mobile phone or
pager. The RMS compact viewer/programmer software uses the TAP ('Telocator Alphanumeric Protocol').
Communication protocol to send messages to the SMS bureau.
Note:
The SMS bureau to be used must support the TAP communication protocol. Your network supplier
should be able to tell you if they have a TAP bureau.
Note:
A Hayes compatible modem installed on the PC running the Viewer/Programmer software is required to
send SMS messages
First, select
SMS
from the
Setup
menu. The following screen should be displayed: