Model 2790 SourceMeter® Switch System Reference Manual
15-5
CALCulate3
:LIMit1
:CLEAR
Path to clear events:
✓
[:IMMediate]
Clear high and low events.
✓
:AUTO <b>
Enable or disable auto-clear.
ON
✓
:AUTO?
Query auto-clear.
✓
:LIMit2
Path to control LIMIT 2 test:
✓
:UPPer
Path to configure upper limit:
✓
[:DATA] <n>
[, <clist>]
Set upper limit (-4294967295 to
+4294967295).
2
✓
[:DATA]? [<clist>]
Query upper limit.
✓
:LOWer
Path to configure lower limit:
✓
[:DATA] <n>
[, <clist>]
Set lower limit (-4294967295 to
+4294967295).
-2
✓
[:DATA]? [<clist>]
Query lower limit.
✓
:STATe <b>
[, <clist>]
Enable or disable limit test.
OFF
✓
:STATe? [<clist>]
Query state of limit test.
✓
:FAIL?
Query test result (1 = failing).
✓
:CLEAR
Path to clear events:
✓
[:IMMediate]
Clear high and low events.
✓
:AUTO <b>
Enable or disable auto-clear.
ON
✓
:AUTO?
Query auto-clear.
✓
Notes:
1. The :MMFactor and :MA1Factor commands perform the same operations.
2. The :MBFactor and :MA0Factor commands perform the same operations.
3. For mX+b and m/X+b units, <char> = one character; ‘A’ through ‘Z’, degrees symbol (‘°’), or ohms symbol (‘
Ω
’).
4. ON is the *RST default parameter and OFF is the SYSTem:PRESet default.
Table 15-1 (cont.)
CALCulate command summary
Command
Description
Default
parameter
Ref
SCPI
Summary of Contents for 2790
Page 3: ......
Page 7: ......
Page 105: ...2 48 Model 2790 SourceMeter Switch System Reference Manual...
Page 245: ...7 40 Model 2790 SourceMeter Switch System Reference Manual...
Page 265: ...8 20 Model 2790 SourceMeter Switch System Reference Manual...
Page 305: ...10 22 Model 2790 SourceMeter Switch System Reference Manual...
Page 328: ...12 CommonCommands...
Page 336: ...13 SCPISignalOriented MeasurementCommands...
Page 345: ...13 10 Model 2790 SourceMeter Switch System Reference Manual...
Page 355: ...14 10 Model 2790 SourceMeter Switch System Reference Manual...
Page 356: ...15 SCPIReferenceTables...
Page 419: ...16 38 Model 2790 SourceMeter Switch System Reference Manual...
Page 461: ...A 2 Specifications Model 2790 SourceMeter Switch System Reference Manual...
Page 462: ...Model 2790 SourceMeter Switch System Reference Manual Specifications A 3...
Page 463: ...A 4 Specifications Model 2790 SourceMeter Switch System Reference Manual...
Page 464: ...Model 2790 SourceMeter Switch System Reference Manual Specifications A 5...
Page 465: ...A 6 Specifications Model 2790 SourceMeter Switch System Reference Manual...
Page 466: ...Model 2790 SourceMeter Switch System Reference Manual Specifications A 7...
Page 471: ...A 12 Specifications Model 2790 SourceMeter Switch System Reference Manual...
Page 472: ...B StatusandErrorMessages...
Page 479: ...B 8 Model 2790 SourceMeter Switch System Reference Manual...
Page 493: ...C 14 Model 2790 SourceMeter Switch System Reference Manaul...
Page 509: ...E 6 Model 2790 SourceMeter Switch System Reference Manual...
Page 510: ...F IEEE 488BusOverview...
Page 525: ...F 16 Model 2790 SourceMeter Switch System Reference Manual...
Page 526: ...G CalibrationReference...