D3-DA 3xx/x
Description of module
Project engineering manual V1.07
23
© KEBA
Tripple axis
3
Power supply
x
DC
0
Cooling
x
Cooling element
A
Cold plate
B
Continuous current
x
1.5 A
01
...
...
32 A
32
Encoder interface
x
None
0
Multi encoder interface
1
Hiperface DSL
2
Safety functions
x
None
0
STO + SBC
1
Version
x
without limitation of output frequency
00
maximum output frequency < 600 Hz
20
Classification, number of axis, rated current and size
Axis
module
with ...
Size 1
Rated current I
nenn, eff
[A]
Size 2
Rated current I
nenn, eff
[A]
1 axis
1,5 A
3 A
6 A
12 A
18 A
-
-
24 A
32
2 axis
2 x 1,5 A
2 x 3 A
2 x 6 A
-
-
2 x 12 A 2 x 16 A
-
-
3 axis
3 x 1,5 A
3 x 3 A
3 x 6 A
-
-
3 x 12 A -
-
-
3.5
Accessories
3.5.1
Connector set
Caution
Only compatible mating connectors that are approved by KEBA must be
used.
The technical data for the terminals are contained in the technical data sheet
of the manufacturer of the female connectors.