D3-DA 3xx/x
Connections and wiring
Project engineering manual V1.07
55
© KEBA
Fig. 6-31: Electrical isolation method
1
... Mains fuse for d.c. link
2
... Mains fuses for switching power
supply of supply module
3
... Mains contactor with protective cir-
cuitry (optional)
4
... Switch contact for for mains contac-
tor (optional)
5
... Power choke (optional)
6
... Mains filter
7
... Power supply of supply module
8
... Main connection (24 V switching
power supply)
9
... Main connection of supply module
10
... D3-DP 3xx/x power supply
11
... D3-DA 3xx/x axis module
12
... Control cabinet
13
... Field
14
... Braking resistor
15
... EtherCAT connection
16
... Conductive mounting plate
17
... PE connection
18
... Conductive mounting plate
PELV
... Protective extra low voltage circuit
BI
... Basic isolation
VI
... Strenghten isolation
ZK
... Low voltage d.c. link
NV
... Low voltage
Information
The electrical isolation method correspond to EN 61800-5-1.
The following conditions apply for safety digital inputs of the D3-DA 3xx/x:
●
The inputs SDI00/SDI01/GND are isolated against SDI02/SDI03/GND.
●
All inputs are isolated against 24 V power supply.
●
All inputs are isolated against PE.
●
Maximum allowed isolation voltage: PELV
●
Maximum allowed input voltage: -60 V ... 60 V