Technical data
Project engineering manual V1.07
93
© KEBA
Maximum current for 2 s:
36 A
36 A
26.4 A
18.4 A
14 A
Maximum current for 500 ms:
48 A
40.8 A
26.4 A
18.4 A
14 A
Maximum current at F
M
= 0 Hz:
31.5 A
26 A
16.8 A
11.7 A
8.9 A
12.4
D3-DA 310/x-24xx, D3-DA 310/x-32xx
Control section
Control voltage:
24 V DC ±10 %
Control voltage on usage of a motor holding
brake with cable length < 50 m:
24 V DC -5 % / +10 %
Inrush current:
max. 1.8 A
Current consumption with power stage (without fan, motor brake or encoder):
●
D3-DA 310/x:
0.9 A
Current output, output motor holding brake:
●
D3-DA 310/x-24xx:
max. 2 A
●
D3-DA 310/x-32xx:
max. 2 x 2 A
Current consumption fan:
700 mA
D.c. link
Capacity:
675 μF
DC resistance in d.c. link (DC+ to DC-):
146 kΩ
Power section
Ambient temperature
5 - 40 °C (upt o 50 °C with derating)
Permissible switching frequencies:
2 / 4 / 8 / 12 / 16 kHz
without motor holding brake with 10 m motor
cable:
3 - 8 kV / μs
Recommended output frequency range:
●
@ 2/4 kHz:
0 - 400 Hz
●
@ 8 kHz:
0 - 800 Hz
*)
●
@ 16 kHz:
0 - 1600 Hz
*)
*)
For Variants with limitation of output frequency the max. output frequency
is limited to 599 Hz.
Axis module
Dissipation @ (400 V / 4 kHz / I
nom
) in the interior:
●
D3-DA 310/A-24xx
103 W
●
D3-DA 310/A-32xx
112 W
●
D3-DA 310/B-24xx:
78 W