D3-DA 3xx/x
Technical data
Project engineering manual V1.07
87
© KEBA
Maximum current at F
M
= 0 Hz:
3.1 A
2.6 A
1.7 A
1.2 A
0.9 A
12.1.2
Current data D3-DA 3x0/x-03xx
Information
Current data per axis in the axis module 230/400/480 V AC refers to the
supply voltage for the supply module.
The value in the following table is output current and specified for each axis
of the respective product variant (see
3.4 Overview D3-DA 3xx/x variants
).
At U
supply
= 230 V und 400 V
F
S
2 kHz
4 kHz
8 kHz
12 kHz
16 kHz
Nominal current:
3 A
3 A
3 A
2 A
1.45 A
Maximum current for 10 s:
6 A
6 A
6 A
4 A
2.9 A
Maximum current for 500 ms:
9 A
9 A
6.25 A
4.85 A
3.8 A
Maximum current at F
M
= 0 Hz:
7.35 A
6.15 A
4 A
3.1 A
2.4 A
At U
supply
= 480 V
F
S
2 kHz
4 kHz
8 kHz
12 kHz
16 kHz
Nominal current:
3 A
3 A
2.6 A
1.35 A
0.6 A
Maximum current for 10 s:
6 A
6 A
5.2 A
2.7 A
1.2 A
Maximum current for 500 ms:
9 A
8 A
5.2 A
3.6 A
2.75 A
Maximum current at F
M
= 0 Hz:
6.2 A
5.1 A
3.3 A
2.3 A
1.75 A
12.2
D3-DA 3x0/x-06xx, D3-DA 3x0/x-12xx
Control section
Control voltage:
24 V DC ±10 %
Control voltage on usage of a motor holding
brake with cable length < 50 m:
24 V DC -5 % / +10 %
Inrush current:
max. 1.8 A
Current consumption with power stage (with-
out fan, motor brake or encoder):
●
D3-DA 310/x-06xx:
0.5 A
●
D3-DA 310/x-12xx:
0.5 A
●
D3-DA 320/x-06xx:
0.7 A
●
D3-DA 320/x-12xx:
0.8 A
●
D3-DA 330/x-06xx:
0.9 A
●
D3-DA 330/x-12xx:
1 A