D3-DA 3xx/x
Technical data
Project engineering manual V1.07
94
© KEBA
●
D3-DA 310/B-32xx:
87 W
Dissipation @ (400 V / 4 kHz/ P
nom
) via cooling element/cold plate:
●
D3-DA 310/x-24xx:
176 W
●
D3-DA 310/x-32xx:
240 W
12.4.1
Current data D3-DA 310/x-24xx
Information
Current data per axis in the axis module 230/400/480 V AC refers to the
supply voltage for the supply module.
At U
supply
= 230 V and 400 V
F
S
2 kHz
4 kHz
8 kHz
12 kHz
16 kHz
Nominal current:
24 A
24 A
20 A
12.5 A
9.9 A
Maximum current for 10 s:
48 A
48 A
45.7 A
31.1 A
22.9 A
Maximum current for 500 ms:
72 A
66.8 A
45.7 A
31.1 A
22.9 A
Maximum current at F
M
= 0 Hz:
53.9 A
39.2 A
26.8 A
18.2 A
13.4 A
At U
supply
= 480 V
F
S
2 kHz
4 kHz
8 kHz
12 kHz
16 kHz
Nominal current:
24 A
24 A
17.1 A
10.1 A
8.2 A
Maximum current for 10 s:
48 A
48 A
32.6 A
24.1 A
19.3 A
Maximum current for 500 ms:
72 A
59 A
32.6 A
24.1 A
19.3 A
Maximum current at F
M
= 0 Hz:
52.5 A
34.6 A
19.1 A
14.2 A
11.3 A
12.4.2
Current data D3-DA 310/x-32xx
Information
Current specification for each axis module 230/400/480 V AC referes to the
supply voltage of the supply module.
At U
supply
= 230 V and 400 V
F
S
2 kHz
4 kHz
8 kHz
12 kHz
16 kHz
Nominal current:
32 A
*)
32 A
31 A
22.5 A
17 A
Maximum current for 1.5 s:
64 A
64 A
62 A
50.8 A
37.4 A
Maximum current for 500 ms:
100 A
100 A
74.8 A
50.8 A
37.4 A
Maximum current at F
M
= 0 Hz:
64 A
64 A
51.4 A
35 A
25.7 A