D3-DA 3xx/x
Technical data
Project engineering manual V1.07
91
© KEBA
Control voltage on usage of a motor holding
brake with cable length < 50 m:
24 V DC -5 % / +10 %
Inrush current:
max. 1.8 A
Current consumption with power stage (without fan, motor brake or encoder):
●
D3-DA 320/x-16xx:
0.8 A
●
D3-DA 310/x-18xx:
0.5 A
Current output, output motor holding brake:
●
D3-DA 320/x-16xx:
max. 2 x 2 A
●
D3-DA 310/x-18xx:
max. 2 A
Current consumption fan:
●
Size 1:
400 mA
●
Size 2:
700 mA
D.c. link
Capacity:
●
D3-DA 320/x-16xx:
405 μF
●
D3-DA 310/x-18xx:
275 μF
DC resistance in d.c. link (DC+ to DC-):
146 kΩ
Power section
Ambient temperature
5 - 40 °C (upt o 50 °C with derating)
Permissible switching frequencies:
2 / 4 / 8 / 12 / 16 kHz
without motor holding brake with 10 m motor
cable:
3 - 8 kV / μs
Recommended output frequency range:
●
@ 2/4 kHz:
0 - 400 Hz
●
@ 8 kHz:
0 - 800 Hz
*)
●
@ 16 kHz:
0 - 1600 Hz
*)
*)
For Variants with limitation of output frequency the max. output frequency
is limited to 599 Hz.
Axis module
Dissipation @ (400 V / 4 kHz / I
nom
) in the interior:
●
D3-DA 320/A-16xx
128.7 W
●
D3-DA 310/A-18xx
102 W
●
D3-DA 320/B-16xx:
95 W
●
D3-DA 310/B-18xx:
66 W
Dissipation @ (400 V / 4 kHz / P
nom
) via cooling element/cold plate:
●
D3-DA 320/x-16xx:
233 W
●
D3-DA 310/x-18xx:
120 W