D3-DA 3xx/x
Mounting and installation instructions
Project engineering manual V1.07
31
© KEBA
Encoder connectors
All encoder cables must be shielded. All available cables from KEBA are
listed in the appendix. For connecting third-party motors, equivalent cables
must be used.
Connectors for the motor
All motor cables must be shielded. All available cables from KEBA are listed
in the appendix. For connecting third-party motors, equivalent cables must
be used.
Connector break resistor
The cables to the break resistor must be shielded and connected to the re-
spective casing on both sides. The shield connection on the supply module
(plug "BR") occurs via the shield plate of the included plug. The break resis-
tor is normally installed in a metal casing. If the break resistor is mounted on
a metallic and conductive base plate, it is possible to manufacture the shield
connection on the side of the the break resistor with a shield clamp on the
base plate, as close as possible to the break resistor. All available break re-
sistors from KEBA are listed in the appendix.
Supply connectors
The supply connector X01A (Line IN) of the supply module must have an ap-
propriate filter. Appropriate filters are listed in the appendix. For demension-
ing on the one hand supply current and on the other hand the sum of the
length of the motor cables are decisive. A shielded cable must be used be-
tween the connector Line IN and the filter. The shield connection on the sup-
ply module occurs via the shield plate on the plug. The connection plug is
part of the supply package of the supply module. The mains filter needs an
appropriate shield connection to the metal casing of the mains filter. This is
achieved if the mains filter is mounted on a metallic and conductive base
plate and if the cable shield is connected to the base plate via a shield clamp
as close as possible to the connector "load" of the mains filter or is con-
nected with the included screw-shield-connection clip on the mains filter.