MULTICAL® 803
44
Kamstrup A/S · Technical description · 5512-2360_A1_
GB
_02.2019
The pulse inputs are configured as a part of the calculator’s configuration number via the FF and GG codes. Upon
receipt of order, the FF and GG codes are configured at 24 by default (unless otherwise informed by the customer).
Valid FF and GG codes appear from the table below. The default code 24 is marked in green. The FF and GG codes
can be reconfigured by means of METERTOOL HCW. See the technical description of METERTOOL HCW (5512-2097).
Input A1/A2
Input B1/B2
FF
code
Max flow
Water meter
GG
code
Max flow
Water meter
Pre-counter
Wh/imp
l/imp
Measuring unit and decimal place
01
100 m³/h
01
100 m³/h
1
-
100
vol A/vol b (m
3
)
000000.0
02
50 m³/h
02
50 m³/h
2
-
50
vol A/vol b (m
3
)
000000.0
03
25 m³/h
03
25 m³/h
4
-
25
vol A/vol b (m
3
)
000000.0
04
10 m³/h
04
10 m³/h
10
-
10
vol A/vol b (m
3
)
000000.0
05
5 m³/h
05
5 m³/h
20
-
5
vol A/vol b (m
3
)
000000.0
06
2.5 m³/h
06
2.5 m³/h
40
-
2.5
vol A/vol b (m
3
)
000000.0
07
1 m³/h
07
1 m³/h
100
-
1
vol A/vol b (m
3
)
000000.0
24
10 m³/h
24
10 m³/h
1
-
10
vol A/vol b (m
3
)
00000.00
25
5 m³/h
25
5 m³/h
2
-
5
vol A/vol b (m
3
)
00000.00
26
2.5 m³/h
26
2.5 m³/h
4
-
2.5
vol A/vol b (m
3
)
00000.00
27
1 m³/h
27
1 m³/h
10
-
1
vol A/vol b (m
3
)
00000.00
40
1000 m³/h
40
1000 m³/h
1
-
1000
vol A/vol b (m
3
)
0000000
FF
code
Max power
Electricity meter
GG
code
Max power
Electricity meter
Pre-counter
Wh/imp
l/imp
Measuring unit and decimal place
50
2500 kW
50
2500 kW
1
1000
-
EL A/EL b (kWh)
0000000
51
150 kW
51
150 kW
60
16.67
-
EL A/EL b (kWh)
0000000
52
120 kW
52
120 kW
75
13.33
-
EL A/EL b (kWh)
0000000
53
75 kW
53
75 kW
120
8.333
-
EL A/EL b (kWh)
0000000
54
30 kW
54
30 kW
240
4.167
-
EL A/EL b (kWh)
0000000
55
25 kW
55
25 kW
340
2.941
-
EL A/EL b (kWh)
0000000
56
20 kW
56
20 kW
480
2.083
-
EL A/EL b (kWh)
0000000
57
15 kW
57
15 kW
600
1.667
-
EL A/EL b (kWh)
0000000
58
7.5 kW
58
7.5 kW
1000
1
-
EL A/EL b (kWh)
0000000
59
750 kW
59
750 kW
10
100
-
EL A/EL b (kWh)
0000000
60
2500 kW
60
2500 kW
2
500
-
EL A/EL b (kWh)
0000000
61
75 kW
61
75 kW
100
10
-
EL A/EL b (kWh)
0000000
62
15 kW
62
15 kW
500
2
-
EL A/EL b (kWh)
0000000
70
25000 kW
70
25000 kW
1
10000
- EL A/EL b (MWh)
00000.00
Inputs for external alarm:
98
98
External alarm input; Alarm=LO (connect function, normally open)
99
99
External alarm input; Alarm=HI (breaker function, normally closed)