MULTICAL® 803
42
Kamstrup A/S · Technical description · 5512-2360_A1_
GB
_02.2019
The table below is a part of the type number overview, which shows the module type numbers. The table
distinguishes between modules with pulse inputs (In-A, In-B) and modules with pulse outputs (Out-C, Out-D).
Modules
Data + 2 pulse inputs (In-A, In-B)
10
Data + 2 pulse outputs (Out-C, Out-D)
11
M-Bus, config 2 pulse inputs (In-A, In-B)
20
M-Bus, config 2 pulse outputs (Out-C, Out-D)
21
M-Bus, confi Thermal Disconnect
22
Wireless M-Bus, configurable, 868 MHz + 2 pulse inputs (In-A, In-B)
30
Wireless M-Bus, configurable, 868 MHz + 2 pulse outputs (Out-C, Out-D)
31
Analog output module 2 x 0/4…20 mA
40
Analog input module 2 x 0/4…20 mA
41
PQT Controller
43
Kamstrup Radio GDPR + 2 pulse inputs (In-A, In-B)
51
LON FT-X3 + 2 pulse inputs (In-A, In-B)
60
BACnet MS/TP + 2 pulse inputs (In-A, In-B)
66
Modbus RTU + 2 pulse inputs (In-A, In-B)
67
2G/4G network 2 pulse inputs (In-A, In-B)
80
Modbus/KMP TCP/IP + 2 pulse inputs (In-A, In-B)
82
High Power Radio Router GDPR + 2 pulse inputs (In-A, In-B)
85
MULTICAL
803 registers the accumulated consumption of the meters connected to the inputs and saves the
counter values every month and every year on target date. The number of these yearly and monthly loggings
depends on the selected logger profile (RR code). Read more about data logger profiles in paragraph 3.4.12. In order
to facilitate the identification during data reading, it is also possible to save the meter numbers of the four meters
connected to the inputs. The meter numbers can be either programmed in the meter via the SETUP loop (for A1 and
B1) or via METERTOOL HCW (for A1, B1, A2 and B2).
Two alarm types are connected to the pulse inputs: cold water leakage and external alarm, respectively. Unless
otherwise informed by the customer, the calculator is, in general, prepared for external alarm on all four inputs from
the factory, but only with one active leakage alarm on inputs A1 and A2. Please contact Kamstrup A/S if you need
leakage alarm possibility on input B1 and B2. Read more about cold water leakage in paragraph 3.4.10 and info
codes in paragraph 7.8.
Note:
Which pulse input registers are collected through the module is controlled by the selected
datagram profile of the module, which is configured through the module's ZZZ code.
By default, In-A1 and In-B1 are collected.