MULTICAL® 803
100
Kamstrup A/S · Technical description · 5512-2360_A1_
GB
_02.2019
0
5
10
15
20
25
jan
feb
mar
apr
may
jun
jul
aug
sep
oct
nov
dec
Ou
tl
et tem
pe
ra
tu
re
Date
Scheduler function
Application no. 9
2 cooling circuits with joint inlet pipe
Cooling energy #1: E4 = V1 (t1-t3)k
t1
Cooling energy #2: E5 = V2 (t2-t3)k
t2
Mass: M1 = V1 (Kmass t1)
Mass: M2 = V2 (Kmass t2)
Config. A = 4 (outlet)
Application no. 10
Energy of domestic hot water
Tap water energy: E1 = V1 (t1-t2)k
t1
Mass: M1 = V1 (Kmass t1)
t1 and t2 are measured with 2-wire sensors or 4-
wire sensors.
Alternative:
t2 is programmed with a fixed temperature value
or t2 is programmed via the scheduler function that
is built into MULTICAL® 803. The temperature t2
follows a table, within which t2 can be changed up
to 12 times a year.
Config. A = 3 (inlet)