10.1.2
Top modules 67-0A, 67-0B and 602-0C pulse outputs
These top modules has two configurable pulse outputs, which are suitable for combined heating/cooling appli-
cations among other things:
Meter function
Output C (16-17)
Output D (18-19)
Pulse duration
Heat meter
CE+ Heat energy (E1)
CV+ Volume (V1)
32 ms
or
100 ms
Volume meter
CV+ Volume (V1)
CV+ Volume (V1)
Cooling meter
CE- Cooling energy (E3)
CV+ Volume (V1)
Heat/cooling meter CE+ Heat energy (E1)
CE- Cooling energy (E3)
Pulse resolution follows the display (fixed in CCC-code). E.g. CCC=119: 1 pulse/kWh and 1 puls/0.01m
3
The module includes the configuration data, which will also follow the module in case of replacement.
CV- (TA3) is only used in connection with tariff EE=20.